    single-channel micro Syringe pump with infusion/withdrawal mode 3

    single-channel micro Syringe pump with infusion/withdrawal mode 3

    - Max. Infusion Distance: 90 mm
    - Acceptable Sample Syringe: 5 µL - 60 mL
    - Linear Speed: 7.9 µm/min - 79.4 mm/min
    - Adjusting Resolution: 7.9 µL/min
    - Distance Resolution: 0.165 µm
    - Linear Force: > 90 N
    - Setting Mode: Membrane keypad and rotary coded switch
    - Control Accuracy: < +/- 0.5% in condition of 30% of the full stroke
    - Display: 128x64 graphic LCD
    - External Control Interface: Start/Stop control, fast forward control, fast reverse control
    - Communication Interface: RS485
    - Power Supply: AC 100 V - 240 V or DC12V
    - Power Consumption: < 10W
    - Operating Condition: Temperature 0 to 40°C; relative humidity < 80%
    - Controller Dimensions (Lx W x H) : 170 x 108 x 70 (mm)
    - Controller Weight: 0.8 Kg
    - Drive Unit Dimensions (L x W x H): 245 x 100x 95 (mm)
    - Drive Unit Weight: 1.3 Kg

    * Prices do not include VAT and shipping
    READ MORE >
    • Working Mode: Infusion & withdrawal
    CATALOG NUMBER: TJ-3A
    £2436
    Free delivery in UK
    • TECHNICAL DATA
    • FUNCTIONS
    • DESCRIPTION
    • ACCESSORIES
    • VIDEOS
    • DOCUMENTATION
    • DOWNLOAD
    • REQUEST A QUOTE
    Channel
    1
    Working Mode
    Infusion & withdrawal
    - Max. Infusion Distance: 90 mm
    - Acceptable Sample Syringe: 5 µL - 60 mL
    - Linear Speed: 7.9 µm/min - 79.4 mm/min
    - Adjusting Resolution: 7.9 µL/min
    - Distance Resolution: 0.165 µm
    - Linear Force: > 90 N
    - Setting Mode: Membrane keypad and rotary coded switch
    - Control Accuracy: < +/- 0.5% in condition of 30% of the full stroke
    - Display: 128x64 graphic LCD
    - External Control Interface: Start/Stop control, fast forward control, fast reverse control
    - Communication Interface: RS485
    - Power Supply: AC 100 V - 240 V or DC12V
    - Power Consumption: < 10W
    - Operating Condition: Temperature 0 to 40°C; relative humidity < 80%
    - Controller Dimensions (Lx W x H) : 170 x 108 x 70 (mm)
    - Controller Weight: 0.8 Kg
    - Drive Unit Dimensions (L x W x H): 245 x 100x 95 (mm)
    - Drive Unit Weight: 1.3 Kg

    * Prices do not include VAT and shipping

    Specifications

     

    Operation Manual

     

    CE

     

    TECHNICAL DATA

      Specifications
      TJ-3A_SPEC.pdf
      Operation Manual
      TJ-3A_OPR.pdf
      CE
      TJ-3A_CE.pdf
      Channel
      1
      Working Mode
      Infusion & withdrawal

    FUNCTIONS

    DESCRIPTION

    - Max. Infusion Distance: 90 mm
    - Acceptable Sample Syringe: 5 µL - 60 mL
    - Linear Speed: 7.9 µm/min - 79.4 mm/min
    - Adjusting Resolution: 7.9 µL/min
    - Distance Resolution: 0.165 µm
    - Linear Force: > 90 N
    - Setting Mode: Membrane keypad and rotary coded switch
    - Control Accuracy: < +/- 0.5% in condition of 30% of the full stroke
    - Display: 128x64 graphic LCD
    - External Control Interface: Start/Stop control, fast forward control, fast reverse control
    - Communication Interface: RS485
    - Power Supply: AC 100 V - 240 V or DC12V
    - Power Consumption: < 10W
    - Operating Condition: Temperature 0 to 40°C; relative humidity < 80%
    - Controller Dimensions (Lx W x H) : 170 x 108 x 70 (mm)
    - Controller Weight: 0.8 Kg
    - Drive Unit Dimensions (L x W x H): 245 x 100x 95 (mm)
    - Drive Unit Weight: 1.3 Kg

    * Prices do not include VAT and shipping

    ACCESSORIES

    VIDEOS

    DOCUMENTATION

    Specifications

     

    Operation Manual

     

    CE

     

    DOWNLOAD

    REQUEST A QUOTE

    blogs

    BLOGS

    ABOUT US

    ABOUT MUNRO

    CONTACT US

    CONTACT US

    SERVICE CENTER

    SERVICE CENTER

    • ABOUT
    • |
    • PRODUCTS
    • |
    • CATALOGS
    • |
    • SUPPORT
    • |
    • SERVICE CENTER
    • |
    • CUSTOMERS
    • |
    • TERMS
    • |
    • FAQ
    • |
    • BLOGS

    met@munro-group.co.uk
    UK: Burnt Mill, Elizabeth Way Harlow, Essex, CM20 2HU UK 44-45

    • The purchase is secured by a standard  
       
    • Bsmart בניית אתרים
    • SAP
    altImg

    • Fully Supported on Chrome*
    • Color Blind Adjusted
    • Heavy Vision Adjusted
    • Regular Display
    • Access Keys MenuAlt + 0
    • Stop Motion
    • Remove Underline Links
    • Press Keys For View Resize
    • Ctrl + Larger
    • Ctrl - Smaller
    • Ctrl 0 Reset Size
    • Enable Disable Keyboard Focusing
    • Reset All To Defualt

    Access Keys

    • Enable/Disable This MenuAlt + 0
    • Skip To Main MenuAlt + 1
    • Skip To Main ContentAlt + 2
    • דלג למפת אתר מונגשת Alt + Shift + 3
    • SearchAlt + 4
    • Contact PageAlt + 7
    • דלג למפת העמוד Alt+5
    • Skip To HomepageAlt + h
    • Skip To Accessibilty MenuAlt + m

    *Firefox users: Use Alt + Shiftnumber

    In order to move between elements, Press - Tabkey, To backtrack press, - Shift + Tab

  • Skip To Main Menu
  • Skip To Main Content
  • Skip To Accessbilty Menu