      Measuring Principle - O2 electrochemical measuring cell, NDIR sensor
      Measuring Range - 0-100% in 0.1% steps
      Measuring time - Approx.. 10 seconds
      Calibration - Simple 2-point calibration
      Measurement - Automatic by needle with integral pump
      Measurement memory - Circulating memory for 1000 measurements
      Interface - USB port
      Software - AtmoCheck® data logger software
      Working Temperature - Gas/ambient 5-40°C
      Dimensions - (HxWxD) 187x106x91 mm (without needle)
      Power supply - Integrated rechargeable battery
      Standard Configuration - Robust carrying case, Battery Charger, Data lead, Intake hose, Suction needle,
      2*Intake needles, 120*sealing tags, USB Stick, User manual and Datalogging software
      (The software requires MS Windows)
      READ MORE >
        CATALOG NUMBER: AtmoCheck-DOUBLE
        $0
        • TECHNICAL DATA
        • FUNCTIONS
        • DESCRIPTION
        • ACCESSORIES
        • VIDEOS
        • DOCUMENTATION
        • DOWNLOAD
        • REQUEST A QUOTE
        Measuring Principle - O2 electrochemical measuring cell, NDIR sensor
        Measuring Range - 0-100% in 0.1% steps
        Measuring time - Approx.. 10 seconds
        Calibration - Simple 2-point calibration
        Measurement - Automatic by needle with integral pump
        Measurement memory - Circulating memory for 1000 measurements
        Interface - USB port
        Software - AtmoCheck® data logger software
        Working Temperature - Gas/ambient 5-40°C
        Dimensions - (HxWxD) 187x106x91 mm (without needle)
        Power supply - Integrated rechargeable battery
        Standard Configuration - Robust carrying case, Battery Charger, Data lead, Intake hose, Suction needle,
        2*Intake needles, 120*sealing tags, USB Stick, User manual and Datalogging software
        (The software requires MS Windows)

        Operation Manual

         

        TECHNICAL DATA

          Operation Manual
          AtmoCheck-DOUBLE_OPR.pdf

        FUNCTIONS

        DESCRIPTION

        Measuring Principle - O2 electrochemical measuring cell, NDIR sensor
        Measuring Range - 0-100% in 0.1% steps
        Measuring time - Approx.. 10 seconds
        Calibration - Simple 2-point calibration
        Measurement - Automatic by needle with integral pump
        Measurement memory - Circulating memory for 1000 measurements
        Interface - USB port
        Software - AtmoCheck® data logger software
        Working Temperature - Gas/ambient 5-40°C
        Dimensions - (HxWxD) 187x106x91 mm (without needle)
        Power supply - Integrated rechargeable battery
        Standard Configuration - Robust carrying case, Battery Charger, Data lead, Intake hose, Suction needle,
        2*Intake needles, 120*sealing tags, USB Stick, User manual and Datalogging software
        (The software requires MS Windows)

        ACCESSORIES

        VIDEOS

        DOCUMENTATION

        Operation Manual

         

        DOWNLOAD

        REQUEST A QUOTE

        Atmo-412219

        Needles 12 Pcs

        Atmo-210070

        Filter for protection against moisture 5 Pcs

        Atmo-210071

        Tube with Luer-Lock connection

        Atmo-210072

        Rubber plates

        Specifications

        MUNRO- Laboratory Equipment UK

        BLOGS

        ABOUT US

        ABOUT US

        CONTACT US

        CONTACT US

        SERVICE CENTER

        CENTRE

        • ABOUT
        • |
        • PRODUCTS
        • |
        • CATALOGUES
        • |
        • SUPPORT
        • |
        • CENTRE
        • |
        • CUSTOMERS
        • |
        • Privacy Policy
        • |
        • TERMS
        • |
        • FAQ
        • |
        • BLOGS

        [email protected]
        UK: Cavendish House, Parkway, Harlow Business Park, Harlow, Essex CM19 5QF UK

        • Bsmart בניית אתרים
        • SAP
        altImg

        • Fully Supported on Chromee*
        • Color Blind Adjusted
        • Heavy Vision Adjusted
        • Regular Display
        • Access Keys MenuAlt + 0
        • Stop Motion
        • Remove Underline Links
        • Press Keys For View Resize
        • Ctrl + Larger
        • Ctrl - Smaller
        • Ctrl 0 Reset Size
        • Enable Disable Keyboard Focusing
        • Reset All To Defualt

        Access Keys

        • Enable/Disable This MenuAlt + 0
        • Skip To Main MenuAlt + 1
        • Skip To Main ContentAlt + 2
        • דלג למפת אתר מונגשת Alt + Shift + 3
        • SearchAlt + 4
        • Contact PageAlt + 7
        • דלג למפת העמוד Alt+5
        • Skip To HomepageAlt + h
        • Skip To Accessibilty MenuAlt + m

        *Firefox users: Use Alt + Shiftnumber

        In order to move between elements, Press - Tabkey, To backtrack press, - Shift + Tab

      • Skip To Main Menu
      • Skip To Main Content
      • Skip To Accessbilty Menu
      • This website uses cookies for the purpose of ongoing and proper operation in accordance with the privacy policy